Cord was not tightened enough by delivery crew.
PF alarm appeared on display. Noticed clicking when cord was moved. Had arced for some time and melted original block. New part slightly different. Only has 3 lugs, old one had six. Stack using washers provided. Take note of colors before disassembly. Use caution while working through access opening. The edges are sharp. Only tools needed are phillips screwdriver, deep socket for lug nuts. Nut driver optional. Hope this is helpful.
Parts Used:
Main Terminal Block Kit
  • Timothy from Spring Valley, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
104 of 166 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Timer would run but the microwave won't start
I first removed the top plate above the microwave door (3 screws), then I removed the plate containing the buttons and clock. The microwave has 3 relay switches and they are in a little holder. The holder was too difficult to remove so I just removed the bottom switch and replaced. The microwave started right up.
Parts Used:
SWITCH
  • Tim from Chicago, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
90 of 145 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave wouldn't turn on but timer worked.
was told buy a repair person to check the door micro switches as it was a common problem. removed the top plastic air grill to get access to the screw that holds in place the control cover. After unplugging the unit, i took out the (2) screws that held in the switches and removed them (3). One switch was a bit melted so i tested it with a 12 volt battery and it was bad. Ordered a new one from Part select and got it fast . Works great .
Parts Used:
SWITCH
  • Steve from Moorhead, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
35 of 62 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would count down but not run
After unplugging the unit remove the control face buy removing the screws. All three door switchs are on a bracket on the left. Remove the two screws holding the bracket in place and pull out. Disconnect the wires from the three switches and test each switch indivually to determine the bad one. I used a multimeter set on ohms.Replace the bad switch with the new one and replace all the wires. Reassemble the unit and you are good to go.
Parts Used:
SWITCH
  • Betty from Kimball, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
29 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Timer & Light on but no operation
It is a undercabinet stovetop microwave. First had to take it down and unplug. Remove the top cover locate the door switch. Used neednose pliers to remove switch. Unplug two terminals.Plug new switch and use pliers to replace back @ same position.Plug in socket temporarily to see if it works.Afterwards if it works.Unplug and replace cover.Ready to be replaced back under cabinet.
Parts Used:
SWITCH
  • Danny from Yanceyville, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
24 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The microwave door was stuck shut, because the p;lastic piece internal was broken...
first of all, ordered the right piece, second, brought the right handyman to help...getting the over/microwave out as one piece took some doing...then the cover of the microwave had to come off...once we got to the piece itself, it was no issue... then putting it all back together...took about two hours...he needed our assistance because of thew weight and the need to pull the units out simultaneously
Parts Used:
Door Open Lever
  • Larry from BEAVERCRK TWP, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would not turn on
To determine which switch was bad, I removed all three switches from microwave. I used a D-cell battery taping two pieces of wire to the POS and NEG ends. Tape the POS end of wire to a flashlight bulb's bottom tip. Tape or twist the NEG end to the bottom of the switch. Connect another piece of wire to the top of switch and touch the side of the flashlight bulb with the other end of the wire; the bulb should come on. Depress the red button on the switch and the light should go out. The switch is good if this occurs. If light does not come on or the bulb does not got out once the red button is depressed, the switch is bad. Now you have determined which switch to order for replacement.
Parts Used:
Micro Switch w/Line Fuse
  • Jacob from Ludowici, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door open lever behind the control panel broke so the door would not open.
As this microwave is part of a wall micro/oven combo, we removed the trim, slid out the microwave and tried for days to figure out how to release the microwave control panel. Through sheer force, we were able to release the lower half of the panel...enough to get our fingers, chopsticks and a flashlight inside to remove the broken lever. It took 2 of us to pull the panel out and replace the lever. I was hoping for a video online of how to remove that control panel but luckily we changed out the broken lever and it's back in working order! Glad we didn't have to trash and entire microwave/oven combo for one broken plastic part...it all works fine now.
Parts Used:
Door Open Lever
  • Carrie from ELLISVILLE, MO
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The elements were not heating up
It was really easy just unplugged it took off the back cover changed the part out put back cover on plugged it in and the elements were working great!
Parts Used:
Main Terminal Block Kit
  • Tanya from KALISPELL, MT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Internal door open lever broke
Remove microwave from wall, removed outer cover which allowed access behind the control panel, was then able to take out the broken lever and with a little maneuvering was able to replace it with the new one. The whole process took less than an hour and was easy to accomplish.
Parts Used:
Door Open Lever
  • James from UNIVERSITY PL, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
sparking from wave guide cover
Disconnected the power cord, removed the outer cover, shorted the two terminals of the high voltage capacitor with the blade of a screw driver with well insulated handle (very important to prevent a bad shock!!),;removed the plastic fan housing for access to the grounding screw and capacitor housing, installed the new capacitor with the reverse of the above steps (but don't reconnect the power cord yet!!}
Now, the most important step of all, reach inside the oven and remove the mica wave guide cover, clean the oven walls thoroughly and clean the inside of the wave guide with clean cloth and water, sand to bare metal any carburized spots on the exit of the wave guide, cut out any carburized spots on the mica cover, replace the clean cover , or order a new one if necessary. It is OK to use the microwave without the cover while waiting for shipment of the replacement mica cover, but be absolutely sure there will be no food spatters on or near the wave guide opening.
Parts Used:
CAPACITOR
  • ARCHIE from RIO VERDE, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Push Button does not open door very well because door latch plastic is starting to split
Plastic trim on inside of the door pops out if you pry with a flathead screwdriver. Then lift door latch out of place and carefully remove the spring. New latch goes back in the way the old one came out. Door trim pops back in.
Parts Used:
Door Latch Hook
  • Daniel from MINNEAPOLIS, MN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven wires arced and caused the terminal block to melt and become detached from the back of the range
Removed the wires that I could, then terminal block. Installing the new terminal block was very easy; however the wires that arced were fused to the terminal bock screws and needed to be cut and new connectors had to be put on the wires to allow them to be reattached to the block safely.
Once all was replaced and reinstalled the oven has worked great. The length of the repair was increased because of the melted parts and having to run to the store to get the new wire connectors big enough to fit on the wires. If we were simply replacing the block and had not encountered the melted ends, it would have been a very quick and easy repair.
Parts Used:
Main Terminal Block Kit
  • Daniel from Falmouth, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Thermostat for oven cook elements. Cooling fan is a misnomer-the fan still worked!
First of all I am not Betty, I am her husband. Second I and a friend pulled the range out of the countertop (which was not necessary). The top can be raised on it hinges and the plate under the burners can be removed by taking out 8 to 19 screws and there is the thermostat looking at you. After doing this once and knowing where the thermostat is, the job could be done in less that an hour.. INSTRUCTIONS: Turn OFF the circuit breaker. Remove the burners. Remove the plate under the burners. Change the thermostat (making sure to place in correct direction as the one removed). Reassemble, turn on circuit breaker, test oven heat.
Parts Used:
Limit Thermostat For Cooling Fan
  • Betty from OLIVE BRANCH, MS
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Everthing works except heating.
This is an OTR microwave oven, needs to be removed to diagnose problem. I did not diagnose problem properly, I searched online for possible causes, read that (99%)percent of the time the interlock switch was bad and replacement should solve my problem. It was also stated to be an easy fix,15- 45 minutes depending on ability. I ordered the relay switch. Took the oven down then removed outer shell. With my multimeter I began to test, fuses(2), interlock switches(3)and transformer. 3 interlock switches were ok, fuses were fine, and had power to the transformer, meter could not read output of transformer because of high voltage, (2300v). I'm down to magnetron (about a hundred bucks) or the touch pad/ circuit board. I have a countertop micro that I'm putting in place of the OTR. As far as Partselect, my item was shipped and delivered on time, instructions for changing that part was quite accurate. Would order from here again, just do my homework first.
Parts Used:
SWITCH
  • Michael from Waynesboro, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.