Sensor – Part Number: 6877A30013V
Sensor
PartSelect #: PS3654111
Manufacturer #: 6877A30013V
Also known as thermistor.
  No Longer Available
Switch Assembly – Part Number: 6600A30003C
Switch Assembly
PartSelect #: PS3529251
Manufacturer #: 6600A30003C
  No Longer Available
ROLLER – Part Number: MHA62753001
ROLLER
★★★★★
★★★★★
(1)
PartSelect #: PS11712156
Manufacturer #: MHA62753001
$17.95
  Special Order
Filter,Air – Part Number: 5230A20040A
Filter,Air
PartSelect #: PS3527502
Manufacturer #: 5230A20040A
  No Longer Available
Turbo Fan – Part Number: 5900A20007B
Turbo Fan
PartSelect #: PS3528580
Manufacturer #: 5900A20007B
This turbo fan is commonly used in the assembly of air conditioners and dehumidifiers. The fan is used to draw air through the unit and move it forward into your home. If your fan is cracked, broken, ...
$10.71
  Special Order
Motor Assembly,AC – Part Number: 4681A20040J
Motor Assembly,AC
PartSelect #: PS3523159
Manufacturer #: 4681A20040J
  No Longer Available
Power Cord Assembly – Part Number: 6411A20001Z
Power Cord Assembly
PartSelect #: PS3529049
Manufacturer #: 6411A20001Z
  No Longer Available
Cover Assembly,Display – Part Number: 3551A20109B
Cover Assembly,Display
PartSelect #: PS3520189
Manufacturer #: 3551A20109B
  No Longer Available
PCB Assembly,Display – Part Number: 6871A20482A
PCB Assembly,Display
PartSelect #: PS3529779
Manufacturer #: 6871A20482A
  No Longer Available
Capacitor,Film,Box – Part Number: 0CZZA20005N
Capacitor,Film,Box
PartSelect #: PS3517201
Manufacturer #: 0CZZA20005N
  No Longer Available
SHROUD ASSEMBLY – Part Number: 4999A10002B
SHROUD ASSEMBLY
PartSelect #: PS3587953
Manufacturer #: 4999A10002B
  No Longer Available
Tube Assembly,Capillary – Part Number: 5211A31003B
Tube Assembly,Capillary
PartSelect #: PS3527188
Manufacturer #: 5211A31003B
  No Longer Available

Questions And Answers for DH404E

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Common Symptoms of the DH404E

[Viewing 2 of 2]
Unit says bucket is full when it isn’t
Fixed by
these parts
Fixing Fixing
Show All
Won’t stay on
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
bucket full light constantly blinking with error code 01 on the display
Unscrew and detached front and back panels, and inside framework holding the sheet metal to the body, after removing the sheet metal, unscrew the box enclosing the control board, use needle nose pliers to unhook the sensor module from the board and place the new sensor into the spots where the old sensor was connected (thermostat area, humidity Sensor, bucket switch, and control board). Close up the unit and your good to go.
Parts Used:
Sensor
  • Seif from DETROIT, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
turbo stopped spinning
Had to pop open the back. The back did not just unscrew and come off. It has to be pried off carefully. Took the turbo off and put the new one on.
Parts Used:
Turbo Fan
  • Cheryl from Bradner, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken roller wheels
released broken wheels from their position using a screwdriver and secured new ones w/ a pliers.
Parts Used:
ROLLER
  • MICHAEL from LEBANON, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
1 person found this instruction helpful.