LWHD2500ERY9 (AWYAUSH) LG Air Conditioner - Overview
Sections of the LWHD2500ERY9
[Viewing 1 of 1]Keep searches simple, eg. "belt" or "pump".

Thermistor,NTC
PartSelect #: PS3528997
Manufacturer #: 6323A20012C
This part is a thermistor assembly and it works in conjunction with your room air conditioner. The thermistor is a sensor that attaches to the control board of your air conditioner. Once attached it w...
No Longer Available

PCB Assembly,Main
PartSelect #: PS3529791
Manufacturer #: 6871A20604A
This control board, also known as a display board, is used for air conditioners. The control board regulates and carries the power to the various air conditioner components. If your control is defecti...
No Longer Available

Clamp,Spring
PartSelect #: PS3522763
Manufacturer #: 3H02932C
The fan blade clamp, also known as a clamp spring, are for air conditioners. The clamp supports the fan blade on the motor shaft. When the motor is running, it signals the shaft to turn and rotate, bu...
No Longer Available
Questions And Answers for LWHD2500ERY9
Be the first to ask our experts a question about this model!
✖
Ask a Question
Ask our experts a question on this model and we'll respond as soon as we can.
Sorry, we couldn't find a match for "".
Here's a guide for finding your model number.
Something went wrong. Please try again later.
Your Question Has Been Submitted!
Our experts will send you an email as soon as your question has been answered.
Common Symptoms of the LWHD2500ERY9
[Viewing 3 of 3]Noisy
Fixed by
these parts
these parts

Show All
Does not shut off
Fixed by
these parts
these parts

Show All
Does not turn on
Fixed by
these parts
these parts

Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
accumulated condensation caused condenser fan failure
Pull the unit out of cabinet. Remove the brace between the blower housing and the condenser frame. Remove the screws securing the the condenser coil to the base and carefully lift and angle it just enough for the broken fan to clear ( be very careful with the refrigerant lines ). Slide the new fan back on the shaft and secure with the sp
... Read more
ring clamp. I used a pair of vice grips to compress the clamp, but be very careful because the clamp can exit the pliers, if the jaws are not perpendicular to the clamp. If you live in a area with high humidity remove the rubber plug at the back of the unit or the condensation will break your new fan. This fan needs some changes in design because the condensation puts too much stress on the plastic that contacts the motor shaft - some metal between shaft and the blades would help.
Read less
Parts Used:
-
Sam from MCQUEENEY, TX
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
17 of 22 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Fan
Part of the fan blade broke on my AC unit and was causing a vibration. This made the AC unusable. The ordered Fan was a perfect OE replacement. I simply removed the outside over and then the fan shroud inside the unit. I carefully repositioned the condenser unit being careful not to damage the fins. Using a pair of pliers, I removed
... Read more
the retainer clip and removed the old fan. The new fan slid right over the shaft. I replaced the retaining clip and then repositioned the shroud. Then I placed the condenser and fins back into place and then placed the cover back over the unit. Worked perfect. No issues. Take your time. Excellent replacement fan!
Read less
Parts Used:
-
April from EASLEY, SC
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers
6 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad thermistor
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from th
... Read more
e grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.
Read less
Parts Used:
-
Cindy from Baltimore, MD
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!