Water on the shelves and the cooling coils froxe up
The problem is the defrost drain line freezes so the defrost water dumps into the rerrigerator.
GE has a retrofit kit that includes the evap cover, fan and a heater. The heater is shoved down the drain tube to keep it from freezing.
This is a known problem for this bar frig with icemaker.
The GE P/N is WR ... Read more 49X10157
For S/N range TG thru VH
I did call a GE rep since I thought it might be a warranty repair
GE has a retrofit kit that includes the evap cover, fan and a heater. The heater is shoved down the drain tube to keep it from freezing.
This is a known problem for this bar frig with icemaker.
The GE P/N is WR ... Read more 49X10157
For S/N range TG thru VH
I did call a GE rep since I thought it might be a warranty repair
Read less
Parts Used:
-
Kai from McLean, VA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Socket set
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!