David
February 24, 2020
I only had the line side feeding the heater assembly, no neutral so the heater and blower were not operating yet the user interface was responding and the tub was rotating. Is there a thermal fuse or high limit? I see nothing listed, small wiring diagram on the dispenser is very basic. Please respond, thanks. 973-951-1158
For model number WM3997HWA/01
Hello David,
Thank you for your question. The high limit thermostat for your model is under part PS3530487, and the thermal fuse is under part PS3528953. We hope this helps.