10660529900 Kenmore Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
I added an ice maker to a 20 year old refridgerator
I added an icemaker kit. Everything I needed was in the kit. The refrigerator was presetup for an icemaker it was just never added. The only problem I had was that the holes for attaching the water solenoid were not pre drilled so I had to drill them myself and use sheet metal screws. The icemaker is working great.
Parts Used:
-
Nicholas from WEST CHESTER, OH
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Socket set
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
intermittent clicking noise; otherwise fridge seemed to be working fine
Googled "intermittent clicking noise" or something similar and consensus was it was either the capacitor or compressor start relay. You-tubed videos on how to replace these. Looked easy. Just unplug them from the condenser and replace. Contacted Part Select and staff said 50% of the the time it was the capacitor, 50% of the time it was the relay. I was in a time crunch so I ordered both and they came in a couple of days. I replaced the capacitor but the clicking noise continued. I replaced the relay and problem solved! Maybe I could have gotten away with just replacing the relay, but I had them both by then and figured with a 10 year old fridge, better replace them both at the same time and be done with the problem. So far, so good.
Parts Used:
-
Peter from EUGENE, OR
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer No Longer Cools
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Parts Used:
-
STEPHEN from FENTON, MO
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken filler tube at threaded connection
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
Parts Used:
-
Matthew from Phoenix, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Filler tube broken and old tube frozen over
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
doesn't that feel great?
Parts Used:
-
Alan from Chino, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers, Screw drivers
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
-
Winston A from Brooklyn, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers
5 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Installing old ice maker in new freezer
I was able to transfer my old ice maker from my old Roper Refrigerator/Freezer into my new Whirlpool Sidekick Freezer. Everything transferred directly except for the water fill tube. I ordered one on line and simply cut it to the right length, removed the cover plate inside the freezer compartment and the little sticker from the outside. Inserted tube and fastened in place with two screws (not provided but was able to use the screws that were in the holes inside the freezer before the ice maker went in. Works great. By not buying the ice maker with the freezer I saved a hundred bucks or so.
Parts Used:
-
Harry from Ten Mile, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Getting Ice Maker to sit in place prior to tightening screws.
Don not completely remove holding icemaker screws. Unit slips over screws and drops down into place and the use nutdriver to tighten in place. Rest of unit was sound and wasn’t replaced.
After icemaker is installed wait for a while and unit self activated and creates ice cubes.
After icemaker is installed wait for a while and unit self activated and creates ice cubes.
Parts Used:
-
George from POWELL, OH
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer section freezing up ( not defrosting )
ordered the parts ,defrost timer and bi-metal thermostat,assumed it would be more practical to replace both than take a chance . watched a video on how to disassemble the control panel and remove the the timer and the back panel of freezer for the bi-metal thermostat,very clear instructions provided .took about 25 minutes to replace both parts and now is working properly again,,Thanks Again PartSelect for the fast service and delivery
Parts Used:
-
John from COLUMBIA, LA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator freezer stopped cooling
Prior to ordering I removed freezer panel and checked for ice build up and fan functionality. Then removed rear panel cleaned lint from everything pulled front panel vacuumed out the condenser. Plugged back in and all seems to work with the exception of compressor. I have a little experience so googled in model number and your site popped up. I looked up part and the site gave me a percentage loved that. I ordered wish I would have rushed shipping as took about 10 days. Installed in less than 30 minutes and all runs great ??
Parts Used:
-
Robert from COALINGA, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer work perfectly, Refrigerator Stopped getting cold, water line froze, there was ice Forming around the condenser in the bottom of the refrigerator behind the drawers
Freezer worked great, refrigerator stopped getting cold and lots of ice formed around the condenser on the bottom of the refrigerator.
First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. I also took all the cold air vents out and cleaned them.
Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. I also took all the cold air vents out and cleaned them.
Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
Parts Used:
-
Richard from STATEN ISLAND, NY
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It was my first time to install a ice maker.
I first read the instruction manual then I watched the installation video. My water line to it was 3/8. Went to the local ACE Hardware to purchase a short peace of 1/4 copper tubing and the fittings to connect them together. It makes ice every 55 minutes.
Parts Used:
-
Gary from MACOMB, OK
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers, Wrench (Adjustable), Wrench set
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
-
Jane from Albuquerque, NM
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers, Socket set
4 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Parts Used:
-
David from Hemet, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when you try and remove the cable assembly. Hope this is helpful.
Parts Used:
-
George from ENDWELL, NY
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!