11088732796 Kenmore Washer Dryer Combo - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
washer was over flowing
unlike the other's that said to take the top control panel off, i turned the machine up side down and was able to reach the valve from the bottom. it does require a good reach in but an average length arm will make it. just take the rubber hose loose from the valve with a pair of pliers, or hose clamp pliers if you are so blessed to have them, then pull the hose loose from the valve, then take the two electrical conectors off noting wich one goes with each side, then a nut driver should remove the valve without difficulty. installing new valve should be the reverse. i was up in running in minutes. it took longer to undo the hoses and reattach the hoses than to replace the valve.
Parts Used:
-
richard from grants pass, OR
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
did not have hot/warm water
I followed the instructions I found on your website. It made it very easy. Easier than if I had tried to do it the way I thought I had to remove the back of the washer. Going through the top panel made removing the bottom panel screws unnecessary.
The experts were correct, the instructions precise. Thank you
The experts were correct, the instructions precise. Thank you
Parts Used:
-
Marcia from Simpsonville, SC
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water was trickling into wash tub
Your video was helpful. I just followed the directions, replaced the valve, put it back together and celebrated spending $28 instead of the $100 deductible on my home warranty. If you're sure of the part you need, just do it.
Parts Used:
-
Brian from McKinney, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Would Not Shut Off
Just took screws on top panel holding the gauges pop the spring like braces holding the body of machine to back panel removed water valve one screw unhooked wireing than replaced new valve in reverse order.
Parts Used:
-
FLOYD from MOUNT VERNON, KY
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Only hot water would be dispensed into the washing machine
took off the rear panel and removed the existing inlet valve and installed the new one. Replaced the rear panel and the machine work better than ever.
Parts Used:
-
Joselin from Port Saint Lucie, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers, Socket set
1 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refill valve leaked continuosly.
Removed the hoses from the inlet valve. Removed screws that hold control panel in place . Removed control panel which exposed two clips that hold the top of the back panel. Removed the ground screw freeing the ground wire, removed the plastic loom which holds a bundle of wires. I next removed the plastic plate that protects the fill valve from splashed water. Removed the screw that holds the valve in place, then removed the wires and the fill hose. Reversed steps to put back together.
Parts Used:
-
Kenneth from Adrian, OR
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Socket set
1 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My washing machine overflowed and flooded the basement
First, I unplugged it and disconnected the water hoses (the water has been off to it for days). Then, I tried taking off the back of the washing machine. This didn't work, and I actually ended up googling instructions and found pretty detailed, illustrated instructions at Popular Mechanics.
You need to unscrew the front panel that contains all of the controls first, flip it up, and unhook it from the back of the washer (via an electronics clip and 2 metal clips). The outer cover can then be taken off. I recommend undoing the internal hose next -- I used adjustable pliers to squeeze the connecter and loosen the hose. Then, unscrew the water inlet valve and take it off.
Putting everything back together literally just means reversing the instructions.
My washing machine is on a raise service, and I still haven't gotten the outer frame completely back in place correctly, but it's not touching anything or creating any problems. It's really only to safeguard parts anyways, so no worries if it's not perfect -- at least it works now!
You need to unscrew the front panel that contains all of the controls first, flip it up, and unhook it from the back of the washer (via an electronics clip and 2 metal clips). The outer cover can then be taken off. I recommend undoing the internal hose next -- I used adjustable pliers to squeeze the connecter and loosen the hose. Then, unscrew the water inlet valve and take it off.
Putting everything back together literally just means reversing the instructions.
My washing machine is on a raise service, and I still haven't gotten the outer frame completely back in place correctly, but it's not touching anything or creating any problems. It's really only to safeguard parts anyways, so no worries if it's not perfect -- at least it works now!
Parts Used:
-
Laura from Sterling, CT
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers, Wrench (Adjustable)
1 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
squealing noise, very little cold water to fill tub, hot water normal
turn off hot and cold water faucets,unplug the power,pull washer out to gain access to rear cover, remove the top control panel screws,push back and lift off, disconnect hot and cold water hoses from inlet valve and remove enough screws from the back panel to remove the valve, disconnect the valve from the tub fill hose (mine had a spring type hose clamp) note the orientataion of the hot and cold hoses and the solenoid connectors for the hot and cold sides,(mine is stamped in the rear cover)reconnect and reassemble in reverse order and check for proper operation.
Parts Used:
-
richard from cleburne, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Screw drivers
1 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The water inlet valve was defective
First I turned off the water to the washer and then removed the hot/cold water hoses going to the washer, unscrewed the water hoses from the washer, and cleaned the wire screens located immediately inside the inlet water valve. This did not solve the problem. Second, I loosened the hex head screws on the back panel of the washer. This allowed me access to the valve. I tested the valve solenoids with my ohm/volt meter and all checked out OK (but this did not make sense). Third, I surfed the web to find out if the symtoms of the washer's problem were the same as experienced by other people. I found several reports of the same symptoms, all which were solved by replacing the water inlet valve. This conformed my original diagnosis although the valve tested as OK. Fourth, I ordered the part from PartSelect, and removed the hose clamp and two mounting screws holding the old valve to the back panel of the washer and removed the old valves. Last, when the new valve arrived, I assembled the new backing plate to the new valve, attached it to the washer's back panel, attached the water hoses to the valve after fitting new rubber seals to the inside of the hoses, and reattached the washer back panel. The washer is working perfectly again.
Parts Used:
-
Kent from San Diego, CA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers, Socket set
1 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water inlet valve not let water in washer
removed the two screw that hold the inlet valve take hose of .the first was takeing the back of than the hoses from back hose on bottom of machine.
Parts Used:
-
Ronald from prince george, VA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water inlet valve went out
My son did the repair. Thank God for Sons who know how to repair things. Worst thing was figuring out how to get the back off, top where dials are had to come off too. the rest was easy according to him..
Parts Used:
-
Sandra from Ash Flat, AR
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers, Wrench (Adjustable), Wrench set
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cold water solenoid would not open much
Unplugged the washer and pulled out from wall as far as hoses would permit. Removed and drained both supply hoses. Removed drain hose and drained. Any water left in the tub will drain here so it's best to make sure it's drained prior to repair. Used pliers to hold the hose clamp and removed. Took screws out of drain hose interface plate and pulled out far enough to disconnect it from the internal hose.
Removed the two front screws of the control console. removed the two top hinge screws on the back. Removed four screws at the bottom of the rear access panel. Had to lift unclip several clamps holding the level hose in the control console and a cable connector. Unclipped various clips in the back panel to free it from wire bundle and such. Lifted the back panel up off of the clips located at the rear base of the control panel.
Removed two screws to free the solenoid assembly from the back panel. Unplugged the connectors to the original solenoid assembly. Disconnected the internal hose from it. Installed screw and plate supplied with the replacement solenoid to configure it with the same orientation as the original. Connected the internal hose and electrical connectors. Reassembled the back in reverse order as diassembled.
Removed the two front screws of the control console. removed the two top hinge screws on the back. Removed four screws at the bottom of the rear access panel. Had to lift unclip several clamps holding the level hose in the control console and a cable connector. Unclipped various clips in the back panel to free it from wire bundle and such. Lifted the back panel up off of the clips located at the rear base of the control panel.
Removed two screws to free the solenoid assembly from the back panel. Unplugged the connectors to the original solenoid assembly. Disconnected the internal hose from it. Installed screw and plate supplied with the replacement solenoid to configure it with the same orientation as the original. Connected the internal hose and electrical connectors. Reassembled the back in reverse order as diassembled.
Parts Used:
-
Dave from Kingsport, TN
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water inlet valve would not shut off on cold side.
I removed the faulty valve after unplugging the AC cord. Two screws, the two water hoses were removed, and the electrical connections were unplugged. The old valve could then be rotated so that the clamp on the fill tube could be loosened and the tube pulled off the valve.
The new valve body seemed to be an exact replacement, but the mounting bracked was slightly different and required drilling two new screw-mounting holes; an easy job.
Before securing the mounting plate to the machine, the fill tube and clamp were reattached, and the electrical connectors plugged in. After connecting the supply hoses and plugging in the AC cord, the machine filled with water properly and everything seemed to be back to normal.
I might have been able to use the original mounting plate, but it had been taken to a different location which was too far away to easily retrieve.
The new valve body seemed to be an exact replacement, but the mounting bracked was slightly different and required drilling two new screw-mounting holes; an easy job.
Before securing the mounting plate to the machine, the fill tube and clamp were reattached, and the electrical connectors plugged in. After connecting the supply hoses and plugging in the AC cord, the machine filled with water properly and everything seemed to be back to normal.
I might have been able to use the original mounting plate, but it had been taken to a different location which was too far away to easily retrieve.
Parts Used:
-
George from Edgerton, WI
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had no hot water flowing into the washer.
I just followed the instructions from a previous customer. Worked perfectly.
Parts Used:
-
Valan from Arlington, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
not cold water
removed top panel and back panel
and then disconect the two wire fromm water inlet
fallow by removing screws.disconect water hose
then put back new part make sure i have all same conected as original put back panel top and back
conected hose for water back and electric .
then i turned 0n cold water perfect work hot water perfect warm perfect. problem fixed.
thanks. pedro
and then disconect the two wire fromm water inlet
fallow by removing screws.disconect water hose
then put back new part make sure i have all same conected as original put back panel top and back
conected hose for water back and electric .
then i turned 0n cold water perfect work hot water perfect warm perfect. problem fixed.
thanks. pedro
Parts Used:
-
PEDRO from DAVIE, FL
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!