Ice maker stopped working
Took off old part and installed new part
Parts Used:
Water Inlet Valve
  • Fred from Las Vegas, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
11 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker quit making ice
I basically followed the instructions offered when i searched for the ice maker. It was relatively easy to do, I undid the 2 screws holding the ice maker to the side of the freezer, the was the tricky part, holding a mirror so i could see the slots of the screws. loosened them, disconnected the electrical connection and reversed the process for the install. It took about 25 minutes and i was back making ice.
Parts Used:
Replacement Ice Maker
  • Barry from Middletown, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked drawer
I slid out the old drawer and slid in the new drawer. Easy as that! I would recommend this website to anyone.
Parts Used:
Meat Pan
  • Jaime from Harrisburg, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not running
After waiting over 2wks for my part to arrive, I purchased the part locally and made the repair the same day as I am still waiting for the part to arrive from you guys. Your customer service really needs improving. I paid for 2 day shipping, what a joke. I will be returning the part as soon as I receive it thanks.
Parts Used:
Cold Control Thermostat
  • Kenneth from SAVANNAH, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven light bulb went dark; it needed replacing
Twisted replacement bulb into place easily. Let there be light!
Parts Used:
Light Bulb
  • Lise from CEDAR GROVE, NJ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch would not allow door to close.
Removed screws holding unit and removed unit. Removed switch from connectors in unit. Replaced unit without switch. On day switch arrived (delivery was prompt) my wife replaced switch by attaching the two connectors and slipping into unit without having to remove entire unit. How easy was that!!!
Parts Used:
Light Switch
  • Charles from Front Royal, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
Parts Used:
Evaporator Fan Motor Kit (120v 60hz)
  • charles from parker, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original Ice Maker quit working.
Loosened the 2 screws a little so that it would slide up and off then unplugged the wire harness.
Installed the new one in reverse order and works like a champ.
Parts Used:
Replacement Ice Maker
  • Gary from Azle, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
my old ice maker leaked at the bottom
it was really easy changing the ice maker. the only trouble i had was the wiring. it was very stiff and hard to route. it did not work at first but that was my fault did not have the connector plugged in all the way.since then it works great.
Parts Used:
Replacement Ice Maker
  • harry from terre haute, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice would not spill into bucket
The repair was very easy. I loosened the two screws holding the icemaker onto the side of the freezer, then unplugged the icemaker. Reversed the order, and it was done. You have to shut the water off first.
Parts Used:
Ice Maker Assembly
  • Fredia from Benton, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer compartment warm / Ice cream soft
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • George from McBee, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken glass insert over refrigerator drawers
I called in because the model # of the refrigerator did not show up on the website. The cust. srvc. rep looked it up and found the part. It was reasonably priced, I received it in a matter of days and it fit perfectly. Thank you! We were preparing to put the condo on the market and broke the shelf while cleaning. It was great to have a resource for a reasonably priced replacement and quick shipment.
Parts Used:
Pan Cover Glass Insert
  • Margaret from McLean, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Big oops when I broke the glass shelf while washing in hot water...too hot
I ordered the part, it arrived within 48 hours. I opened the fridge and put the shelf in perfectly!
Parts Used:
Pan Cover Glass Insert
  • LYNETTE from AGOURA HILLS, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator crisper pan cover cracked in the front center.
I removed the glass from the cover, removed the 2 crispier pans and removed and discarded the broken cover. I installed the new cover by making sure the back was flush against the back wall of the refrigerator. After that I replaced the glass and drawers and it was as good as new.
Parts Used:
Crisper Pan Cover
  • Linda from VIRGINIA BCH, VA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
Parts Used:
Evaporator Fan Motor Kit (120v 60hz)
  • Denver from BLAIRSVILLE, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25331143300
61 - 75 of 549