Back
Back
Keep typing for more specific results...
Models > 31461-1 > Instructions

31461-1 General Electric Refrigerator - Instructions

All Instructions for the 31461-1
61 - 75 of 79
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
door shelf end cap broke off
easily popped the new one in.
Parts Used:
Door Shelf End Cap - Left Side
  • Leonard from Niagara Falls, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Starter/overload assembly and run capacitor were bad
Removed rer cover, unplugged starter assembly from side of compressor and replaced unit with a new one. Plugged fridge in and it works good.
Parts Used:
Refrigerator Run Capacitor
  • Colby from Blanding, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator and freezer drawer would not maintain set temperature
Condenser fan motor was running slow. This was not a problem included in your list of possible problems. I thought that maybe the capacitor was bad but have no way to check it. So I ordered one. when I received it, I installed it. That was not the problem. So I ordered a fan motor and installed it. That was not the problem. So finally I ordered a control board and installed it. That solved the problem. So maybe you should put "cond.fan motor runs slow" in your list of possible faults and what causes that problem. Capacitor was easy to install, simply remove the cover plate, flip off retaining wire, unplug the capacitor and replace. Fan motor was a bit more difficult. It must be removed from mount after fan scroll is removed. Remove one screw that holds scroll, bend the top down and remove. Then pull hard on fan blade to remove it. It must be installed on new motor. Two screws in frame mount can be removed with some effort if you have a 1/4" drive ratchet with a Phillips screwdriver bit. Then pull frame open and install new motor. Push fan blade on new motor shaft hard. Replacing control board was easy. I used a pair of long nose pliers with 90 degree bend to get mounting pins closed to pull board off.
Parts Used:
Refrigerator Run Capacitor
  • James from Bel Air, MD
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
Was this instruction helpful to you?
Thank you for voting!
Freezer work refierator compartment is warm
Defrost timer is hidden in the control panel in the refrigerator top middle. Turn to off and remove two screws which are hidden behind white tabs. I had to pry the old timer from the plug with a screw driver because it was tight. Try not to short across the terminals. Plug in the new timer. Replace it in the clip where you got old one and reinstall the controls. The freezer was still all frosted up so I had to remove the cover and defrost it with a hair dryer to get it to work. Then I turned it on and it works great.
Parts Used:
Defrost Timer - 120V 60Hz
  • KIRK from Malibu, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Frezzer would freeze up, refrigerator stayed cold, solved the problem. Now the refrigerator seems to be running more than usual.
Checked the defroster coil which is located behind the rear panel in the freezer compartment, it was still working. Followed the schematics down to the defrost timer, which is located in the lower front of the refrigerator and tried that. Plugged in the new part and the problem is solved.
Parts Used:
Defrost Timer - 120V 60Hz
  • Henry from West Seneca, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
the new motor was slightly larger than the old one and the bracket does not fit
Had to get behind the refrigerator and clean the drain out first and that took at least and hour. Just unplug the old motor. Took the old parts of the old motor, put them on the new one and plugged it back in.
Parts Used:
Evaporator Fan Motor Assembly
  • Patricia from Oxford, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 31461-1