refrigerator running all the time
Followed the video and installed the new Jazz board. The board cam in 1 piece which had to be separated into two pieces, but the scored area on the board made it less intimidating. At the same time I replaced the two incandescent lamps in the refrigerator area with LED lamps. Getting the housing for the control board apart was the most difficult part, installing the replacement board was a breeze.
Parts Used:
Refrigerator Electronic Control Board
  • Steve from SOUTH ST PAUL, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The water supply line to the ice maker kept popping off after I replaced the water filter because an "ice plug" had formed in the fill tube, unbeknownst to me.
1. Turn your water OFF and pull the refrigerator out from the wall so you can access the back.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you can gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
Parts Used:
Refrigerator Ice Maker Fill Tube
  • Michael from TAKOMA PARK, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would cool for a very short period of time. Then the compressor would shutdown via internal thermal overload or high head pressure. This was caused by the lack of airflow across the condenser coils and compressor.
(1) Slide out appliance and remove power source. (2) Removed lower access cover on rear of refrigerator. (3) Disconnected plug to the condenser fan motor. (4) remove blades by pulling gently forward (5) remove mounting hardware holding the fan motor (3 screws) (6) motor is now free and new motor can be installed
Parts Used:
Condenser Fan Motor
  • Daniel from RICHTON, MS
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
9 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Parts Used:
Refrigerator Door Switch
  • Duncan from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Both compartments of the refrigerator were warm.
We came home from a long vacation to discover a warm refrigerator with its contents in various stages of decay.

Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.

It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.

But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.

I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Parts Used:
Refrigerator Compressor Start Device And Capacitor
  • Bill from KINGSPORT, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
RH door closure broke
Removed the door and replaced the broken door closure bushing. I had courteous help and responce from Parts Select people. Excelent turn around time on parts delivery.
Parts Used:
Refrigerator Door Closer (White)
  • Estel from Luling, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
10 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken black plastic spring mechanism inside freezer rail
Remove rail and removed broken black plastic spring mechanism with new one and then replace rail.
Parts Used:
SLIDE
  • Ronald from WESTERVILLE, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Control noisy when opening and closing removed damper housing
Pop off vent cover remove 2 screws removed cover housing and foam. Removed damper by unclipping tabs on left and right side of control lift up and out. Unplugged power wires reinstalled in reverse order.
Parts Used:
Refrigerator Damper Control Assembly
  • Nelson from CATSKILL, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy damper
Easy fix, it's right in the back of the fridge under a cover that just clips in, a piece of foam, and two screws. The hardest part is getting the clips free without breaking them. After replacement it's silent instead of making a grinding noise regularly.
Parts Used:
Refrigerator Damper Control Assembly
  • Keith from OLYMPIA, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken light switch
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Parts Used:
Door Switch
  • Terry from WARMINSTER, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Parts Used:
Refrigerator Door Switch
  • Dave from Manchester Center, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wife used vacuum cleaner and busted blade off fan
Instructions were great five minutes to remove and replace fan....Thank You............ saved big money
Parts Used:
Fan Blade
  • Robert from GOSHEN, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Thought motor was bad freezer cold fridge hot
Ordered new fan motor
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Parts Used:
Freezer Evaporator Fan Motor 115v 60hz
  • Wayne from PENNINGTON, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broke the Rocker Switch in Fridge side
Popped out with butter knife and unplugged 3 prong connector and reversed with anew switch.

But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.

Maytag should recall that Rocker Switch and build with better materials.
Parts Used:
Door Switch
  • Sung-Su from BISMARCK, ND
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
FREEZER WOULD NOT DEFROST.
I initially tested the heating element and defrost thermostat using an ohm meter. the defrost thermostat was incased in ice, so I replaced it first. The refridgerator worked for about a week and then froze up again. I then replaced the thermistor and the unit is working as designed.
Parts Used:
Thermistor
  • JEFF from SEATTLE, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!