The fan got very noisy.
My husband did the repair in 45 minutes and said it was very easy. The video made everything plain and simple.
Parts Used:
-
Carol from ORANGE, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer is too hot
Open the freezer panel which attached with screwws and locate the defrost thermmostate behind the back pannel. Cut off the old thermostat wires and connect the new wires.
Parts Used:
-
David from New York, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
4 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Crisper Drawer Cover was broken, and i wanted to add a third shelf for my garage fridge
I slid the old crisper drawer cover out, and slid the new one in. Then I respaced the other shelves, making room for the third shelf, and put the new shelf in. Apart from the time it took me to unpack the boxes these parts came in, and to remove my groceries from the fridge, the "repair" itself took all of about 90 seconds.
Parts Used:
-
Joseph from HAYDEN, CO
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
Parts Used:
-
Catherine from SEATTLE, WA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Parts Used:
-
Roscoe G from ROCHESTER, NY
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the evaporator fan motor was making noise sometimes, but not all the time during the cooling cycle
after watching how easy it was to get to the evaporator fan motor on u-tube, I took out the motor to inspect it......the motor had about 1/8 inch shaft end play and a slight amount of play on the shaft, the rubber grommets looked OK.....I then put it back together......since the motor was the only moving part in this location I figured it had to be the part making the noise, so I ordered a motor and 2 grommets …...the replacement motor also had 1/8 inch end play on the shaft, but no play on the shaft....I installed the new parts and it has been a week now and no noise.....SUCCESS!...….the shaft on the motor protrudes from the motor, and the fan is mounted about 1 1/4 inch away from the bearing in the motor and the fan is unsupported, so I ASSUME that the slight amount of play on the shaft caused some harmonics which caused it to make noise some of the time, but not all of the time......
Parts Used:
-
Kenneth from SEATTLE, WA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Howling motor
Open freezer, remove rack....this got a little complicated because I had to remove the door, that required the offset screwdriver because I had a clearance issues preventing the door from opening all the way. Remove the panel covering the fan, unplug the fan, remove it from bracket, install new fan, plug in, replace panel, replace rack, replace door...bam all done!
Parts Used:
-
Gregg from COEUR D ALENE, ID
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Was getting too cold
Was only two screws after that carefully took the part away unplugging the wires at the same time was plugging in to the new part and was done after 5 or 7 min
Parts Used:
-
Jose A from WEST PALM BCH, FL
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights blown out
-
Gerald from WINTERVILLE, GA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
6 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer just cool but could not freeze the water and the front of door is quite hot to touch.
First I observe that the compressor motor is running since the freezer is cooling. The purchase of the condenser fan is initiated and when the part arrive it is just easy to reinstall the replacement condenser fan.
The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.
The refrigerator as of now is running in perfect condition!
The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.
The refrigerator as of now is running in perfect condition!
Parts Used:
-
Fred from FLUSHING, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The bottom shelf that covers the crisper drawers was cracked.
This was so easy. Got the model number off the refrigerator door. Internet searched and found this website. Ordered the part. Waited maybe 3-4 days for it to arrive. Opened the box, open refrigerator door remove old broken part, install new part and reinstall the drawers. Piece of cake!! So glad I didn’t have to replace a perfectly good refrigerator. Thank you.
Parts Used:
-
Joseph from BRENTWOOD, CA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken crisper drawer cover
After removing all items from the broken top, I removed both drawers and crisper top. I then slid the new top in place and replaced the drawers which easily slid into the grooves in the underside of the top.
Parts Used:
-
Wanda from HOUSTON, TX
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
Parts Used:
-
Jodi from Benton Harbor, MI
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Parts Used:
-
paypal_shipping_address from Ripon, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the condenser fan motor was intermittently verynoisy. obvious sign of a (possibly imminent) failure
1 unplug the appliance
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
Parts Used:
-
Herbert from POCONO LAKE, PA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!