Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Water dispensed, but no ice.
We have a side-by-side and the tutorial was different than what we have. Had trouble getting cover off, but finally repaired and WE HAVE ICE! Also took longer than expected.
Saved a lot!
Parts Used:
Ice Maker Control Assembly
  • NANCY from VALLEY VIEW, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would not cool down. Evaporator fan inop.
Unplug, then remove shelving and rear panel. Remove fan motor, swap wired and install new motor. Reinstall in reverse order. Plug back in and verify the fan is running. Easy and nothing special. Only thing I would caution is they use a foam runner to the refrigerator that may be iced up. Carefully clean the ice out before reinstalling everything. A follow up note. If the fan has not been running, Ice will build up in the drain tube. When you start up the refrigerator, you will see water dripping into the lower shelf. This is easy to fix. Unplug refrigerator and disassemble to where you can see the coils. There will be ice on the bottom covering the drain line hole. You will need to carefully chip away the ice, then use a hair dryer to melt the ice. Carefully use a pointed tool to push in the drain tube until the water drains. Go slow and be patient. Heat is your friend when doing this.
Parts Used:
Refrigerator Evaporator Fan Motor
  • David from SHARPSBURG, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old motor has built in wire harness. The new motor has connectors on it.
Remove and clean out everything from the freezer and unplug the refrigerator. Take out the wire shelf in the freezer. (The fan motor is behind the back wall of the freezer, SO YOU CAN KEEP THE REFRIGERATOR CLOSED). Pop off the little cover on the center of the plastic shroud. Remove the little screw and carefully remove the plastic shroud. Remove the plastic cover for the optional ice maker on the upper left corner of the back wall. Take out the two screws in the upper corners on the back wall of the freezer and the last two screws holding the fan motor. The fan motor won't drop, remove the back wall and you will see two screws holding the motor mount. Remover those two screws, and pop the bracket out and separate.Take the two rubber motor mounts off the ends of the old motor and install them on the new motor. (Now you will have to cut the wires off the old motor), unplug the little wire harness, strip the ends and crimp on wire connectors to plug them onto your new motor. Its an AC motor so it shouldn't matter which hot goes on which of the two terminals. JUST MAKE SURE THE GROUND IS CORRECT! (After reinstalling the motor, plug in the refrigerator, turn it on before installing the shroud and make sure the fan is blowing outward. If all is correct, turn the refrigerator off, unplug and finish assembling the freezer. I found the new motor seems to run more efficiently than the old one.
Parts Used:
Refrigerator Evaporator Fan Motor
  • Leo from EAGLE, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Parts Used:
Refrigerator Water Tube Kit
  • Monica from EDMOND, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old water filter cap was damaged due to trying to turn it too much when trying to install new filters during the last 10 years
This site is so fantastic they even provided a video on how to install the cap. A job well done from a company who cares that you do it right. .
Parts Used:
Refrigerator Water Filter Cap
  • John from CONCORD, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge would not defrost creating ice buildup and fridge would then get warm
My brother came up and installed the part.
Parts Used:
Refrigerator Bimetal Defrost Thermostat
  • Susan from Madrid, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor was making loud noise.
Unplugged refrigerator, Removed lower back panel, Removed fan from fan bracket, Installed new fan to fan bracket, Installed new wire assembly to fan, Replaced back panel. Plugged refrigerator back in and it works great. Only tool needed was 1/4" socket.
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • Stephen from Purcellville, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge ouit cooling
where the wires crossed at the start relay, 20 years of vibration allowed them to short out and burn out the start relay ..since i have 2 identical fridges i switched the run capacitor to determine it was'nt bad too...ordered a start relay wednesday nite and got it friday morning...cold fridge by noon...good service and the part was exactly the same as the original....
Parts Used:
Refrigerator Start Relay
  • danny from adelanto, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
9 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Parts Used:
Refrigerator Door Switch
  • Duncan from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stopped Making Ice
Easy removal. Easy Plug and play install. Didn't even have to use the other wires. After install, put 4 oz of water into ice maker and wait....it didn't start making ice right away, but a couple hours later I heard the wonderful "ice dropping into the bin" sound. Worked great ever since.
Parts Used:
Replacement Ice Maker
  • John from Chandler, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
stop making ice
1.removed 3 nut screws-2 on top &1 on bottom.
2.unplug ref. from outlet.
3.unplug the wires from ice maker to ref.
4.remove ice maker
5.rinse new ice maker
6.plug ice maker to ref. using included wires
7.screw 2 top nut screws first then the bottom.
8.plug ref. back to outlet
9.made first ice in about 2-3 hours
Parts Used:
Replacement Ice Maker
  • Ricky from Philadelphia, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raise side of fridge and slide 2x4 under side with broken wheel.
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.
Parts Used:
Cab Roller
  • Hans from OGDEN, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Parts Used:
Light Socket Kit
  • Wayne from Arlington, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leakiong water from the freezer compartment into the lower refrigeration compartment
After unplugging the appliance, I unscrewed the screws in the bottom and the back of the freezer compartment and un-clipped the connector for the ice machine, which i do not have installed. I clipped the pink and brown wires and replace the switch with the new switch. unfortunately, the appliance is still dripping water from the freezer compartment. It worked for a couple of days then stopped working. Still looking for a true FIX.
Parts Used:
Refrigerator Bimetal Defrost Thermostat
  • Mark from indianapolis, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer constantly covered with ice not defrosting
I opened rear wall inside freezer (two screws) cut the wires on old thermostat and removed it. Then I attatched the new thermostat to the existing wires using wire nuts and electrical tape and slid it onto the copper tubing. Re-installed the rear wall. Freezer works like a charm and the refridgerator is also colder. Job completed in twenty minutes and Tim Allen has nothing on me. Mike Milne
Parts Used:
Refrigerator Bimetal Defrost Thermostat
  • michael from millstone, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ET2AHTXMT00