Compressor overheating - Fridge not Cooling
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Parts Used:
Condenser Fan Motor - 115V
  • CHRIS from LAGUNA NIGUEL, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor rattled loudly
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Robert from Kingwood, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker did not work
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
Parts Used:
Refrigerator Outlet Valve Kit
  • Kenneth from Bellevue, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Parts Used:
LIGHT SWITCH
  • Stephen from Jupiter, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
LIGHT SWITCH
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Parts Used:
Condenser Fan Motor - 115V
  • PERRY from VANDERBILT, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Wrench set
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light in the refrigerator went out
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.

Getting on the internet was so easy. This was really very simple. Thank you for making what I thought would be a big ordeal into something very simple.

Paulette Johnson
Parts Used:
Refrigerator Light Socket
  • Paulette B. from Santa Ana, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Parts Used:
Condenser Fan Motor - 115V
  • JEFF from HAMPTON, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
botton half of refrigerator not cooling
easy as 1.2.3 remove and replace before even thinking. just to let you know i also do this for a living but it is one of the most difficult thing when you have to stop and fix your own
Parts Used:
Defrost Timer - 120V 60Hz
  • HANCEL from ELMONT, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
25 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Cap Broke
It took me about 15 minutes to complete the repair, 1st I emptied the ice maker, then I removed 4 screws from the rear of the ice maker tray and took the plastic piece off of the auger. I reversed the steps and put it back together.
Parts Used:
Ice Dispensing Drive Cup
  • TIM from GRETNA, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bucket drive shaft disengaged from motor drive
This is a 25 year old unit. The ice bucket had warped over time causing the face plate to move forward of its ideal position pulling the entire assembly out of the drive. Removed dispensing unit face assembly. Removed drive shaft assembly. Replaced all washers. Reversed old broken drive cup. Married old drive cup to new drive cup...lining up drive slots. Drilled 6 ea. 3mm holes evenly spaced around circumference into the face of the old drive cup. Fastened drive cups together in vice and with C clamp...then using phillips head screws installed 3 ea. from opposing entry points on each side of this homemade shaft extender. This "mechanism" increased the effective length of the dispensing shaft assembly allowing for a proper fit of the drive shaft to the motor drive connection. Unit now works perfectly. Total cost @ $40.00 and two hours work which would have taken less than one hour if I had remembered to install the ice bucket seal the first time. New ice bucket would have cost @ $185.00. Home warranty does not cover ice makers or any of the associated parts. DIY...it isn't that difficult.
Parts Used:
Ice Bucket Seal Ice Dispensing Drive Cup Roll Pin Dispenser Blade Rest Icemaker Auger Assembly Spacer Blade
  • Paul from Ashton, MD
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking Valve on Ice Maker
I ordered the part and it got here very quickly. Being a novice home repair person, it took me awhile to get the courage to start. It was practically uneventful, but it did take some time to figure it out exactly. I did have to bend the piece some, which is always a little nerve wracking. However, the part is working beautifully and I feel good about myself.
Parts Used:
Refrigerator Outlet Valve Kit
  • Linda from Montgomery, AL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
Parts Used:
LIGHT SWITCH
  • Mark from Somers Point, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator did not cool
i put a new evaporator motor in and now it works fine
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Carl from Kent City, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water under refrigerator, leaky ice maker water supply solenoid valve
This is a relatively simple repair, but requires a bit of running around your house and sitting in a likely cramped space on the floor behind your refrigerator. These steps assume you have verified the valve is leaking and not the lines. 1. Locate where the water line to the fridge connects to the house plumbing. Close the next valve in the house plumbing upstream of this connection. Open some fixture (likely the cold on the kitchen sink) to relieve water pressure in this section of plumbing. Water should flow briefly, then dribble and stop on its own. 2. Unplug your fridge. There are moving parts (a fan) close to the valve that may injure you while you are working. 3. Pull your fridge away from the wall enough so you can scoot behind and sit behind. 4. Gather your tools and parts and squeeze behind the fridge. 5. Remove the felt paper dust cover. Carefully collect the screws. 6. Take a picture of the electrical connection to the valve or make a mental note. 7. Carefully unclip lines from the fridge and remove screws holding valve to fridge body. Slicing a line will create a new problem to fix. Carefully collect the screws. 8. Remove electrical connection. Grasp the connector and pull firmly. Do not yank the wires. 9. Over the bucket, disconnect old valve from lines. Some residual water will flow out. If the stream is steady, double check that Step 1 is completed correctly. Set old valve aside. 10. Examine new valve to determine water input and outlet. There may be an arrow indicating flow direction. 11. Seat the input line in the valve input firmly and connect. Mine was a nut I tightened with a small crescent wrench. 12. Seat the outlet line in the valve outlet firmly and connect. Mine was a push in quick connect. 14. Rest the valve over the bucket. Get up and turn the water back on. Verify your connections are not leaking. 15. Review your picture and reconnect the electrical connection. 16. Install the new valve onto the fridge body. Mine was a different geometry that required some gentle bending of the mounting bracket. Reclip lines to fridge. 17. While you're down there, vacuum underneath your fridge. 18. Reinstall felt paper dust cover. 19. Plug fridge back in. Clean up. 20. Monitor your ice maker, verify good operation. When satisfied, push fridge back. Recycle(?) old valve. 21. Success!
Parts Used:
Refrigerator Outlet Valve Kit
  • Eric from Chicago, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
8 of 8 people found this instruction helpful.