There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Parts Used:
-
Lori from Chuluota, FL
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
12 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frig would not get cold
I watched video for repair and it went just like it showed. piece of cake
Parts Used:
-
dennis j from TOMAHAWK, WI
-
Difficulty Level:Very Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
10 of 12 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer no staying cold
Replaced the electronics board. Fairly easy job. Video helped enormously. Programing is awkward.
Parts Used:
-
William from EXTON, PA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
9 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken light switch
-
Richard from West Warwick, RI
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
12 of 19 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Breaks relatevely often when you accidently have either draws overloaded or open both of them at the same time
You need to lift up the glass part and simply fit it the center rail in, very simple
Parts Used:
-
Aggie from Prospect Hts, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
9 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
Parts Used:
-
Kenneth from Newton Grove, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
10 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wouldn't cool
First I removed the six screws from the cover. I then disconnected the two wires and pulled the small motor out with its base and removed two screws that hold it in place. I then changed the old one for the new one and set it back in its place. I then set the cover back and turned it on. I was happy again.
Parts Used:
-
Fidel from Forest, MS
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
10 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge would not start
Unplug the fridge then wheel the refrigerator out to where you can get to the back - you will probably have to disconnect the ice maker water hose. Using the nut driver remove all the screws from the lower panel on the fridge. You will not have to remove the water hose connection just move the panel around a little. Look on the left side (facing the back of the fridge) you will see the capacitor held onto the compressor with a spring clip. Just pull the clip toward you and that will free the capacitor. Pull up on the capacitor and that will unplug it from the compressor. Be careful not to touch the two poles on the old capacitor. Capacitors store electricity and it could give you a jolt. I used electrical tape to insulate the poles and then threw it away. Plug in the new capacitor- re-hook the clip, reinstall the back panel, plug it in and verify that the fridge is working. Hook your water hose back up and move it back into place and you are done.
Parts Used:
-
Glen from PT CHARLOTTE, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
8 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would not cool,freezer worked.
Took too panel down. Remove.bulbs . Unplugged refrigerator. Removed electronic control board .installed new electronic control board. Plugged in refrigerator , programmed control for ice in about 1 hour refrigerator went to work and got cold Simple operation. Donald Harrell, Don's Repair Service .
Parts Used:
-
Donald from SAN SABA, TX
-
Difficulty Level:Very Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
9 of 12 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Glass shelf had shattered and needed replaced
The repair was just unpacking the glass and placing it on the frame inside the refrigerator. Unfortunately, the shelf was listed by photo and not dimensions for the model number submitted and is approximately 2 inches short. Had I known the dimensions ahead of time, I would not have placed the order.
Parts Used:
-
Martha from Jacksonville, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
8 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Parts Used:
-
Michael from East Meadow, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
7 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The frost free drain behind the freezer compartment clogged and water collected in the bottom of the freezer and eventually came out the door on the right front of the refrigerator.
The other instructions and the video provided by Parts Direct are pretty good with instructions, but they omit two steps. First, if you have an ice maker, you will need to unplug the connector on the back side of the panel you remove at the back of the refrigerator to access the drain tube. Just unplug it and you can move the removed panel to the side without disconnecting any of the water lines. Second, the instructions say to just reconnect the "bottom end" of the new p-trap drain to the drain pan at the bottom of the refrigerator. They don't tell you there are two places to connect the new p-trap to the drain pan. The original tube/trough connected to the one at the back of the drain pan on the left (viewed from the rear of the refrigerator). At first, it looks like the new p-trap won't reach to it for the connection, but if you look closer, there is another connector to the right of the original one that the p-trap connects to properly. Replacing the drain trough with the new p-trap was actually pretty easy and would only take about a half hour. Add another half hour to give the refrigerator coils a good cleaning as they will need it now that you can reach them. The real time consumer, 3 to 4 hours, is needed to use a hair dryer to melt and clear the ice from the condenser at the back of the freezer so the water can drain. Just take your time and all the ice will eventually melt and drain out so the new p-trap will work properly.
Parts Used:
-
David from ROSEBURG, OR
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
7 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking water onto floor
replaced the poorly designed "duck bill" drain with this P trap. Very simple repair done by accessing through the back of the refrigerator. The video on this website walked me right through the repair. It did however fail to mention that the ice has to be removed from the inside. I had to remove the drawer face and pull outs. Then the ice maker and back panel are removed. I used a heat gun and screwdriver to chip and melt the ice build up. If one had the luxury of having another refrigerator to move food in to you could just unplug the unit until the ice melts.
Parts Used:
-
Mark from ALTO, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
7 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer temperature goes down to -20*F before compressor stops but refrigerator side remains normal 38*F and compressor makes a grunting noise while running.
Unplug ref then remove lower(freezer) panel plus trays and thermistor’s cover/holder then remove the evaps cover. I found the evaps all frozen up. Cut and remove old thermistor, strip wires 1/2 inch then cut the new thermistor wires to length and strip 1/2 inch, use the enclosed insulated crimp type connector and put back everything in the reverse order. It works great afterwards.
Parts Used:
-
Aquilino O from VALLEJO, CA
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch in freezer side got broken
Took a putty knife and
Removed the old switch removed the spade terminals from the old switch and replaced them on the new switch and just pushed the new switch back in place
Removed the old switch removed the spade terminals from the old switch and replaced them on the new switch and just pushed the new switch back in place
Parts Used:
-
Doug from PLEASANT VIEW, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!