Ice not dispensing
Ice was not dispensing. Examined the ice bin and auger, noted that the plastic ring that holds the auger at the front of the bin was broken all the way around. Pulled out old bin, making sure the ice fill level was raised all the way up, and pushed in the new bin. The new bin filled with ice, which promptly turned into a solid mass of ice because the ice maker was also faulty. I replaced that as well and have not had any issues.
Parts Used:
Ice Container and Auger Assembly
  • Will from Katy, TX
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not holding temp
The repair could not be completed. I ordered a thermostat defrost kit but received a collar arbor for a saw. They do not answer the phone at customer service and the order took close to two weeks to get in the first place. Beware of shopping at this site!
Parts Used:
Defrost Thermostat Kit
  • David from MILTON, DE
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.

After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.

I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.

I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Parts Used:
Evaporator Fan Blade
  • Bruce from MARTINEZ, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Routine 6 month maintenance
Removed the old filter and took off the water caps and pushed it in place. Then I used a pitcher to clear the air from the line and we are good to go for 6 more months
Parts Used:
Refrigerator Water Filter
  • Richard from Lakewood, OH
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker would not dispense cubes, stuck on crushed ice
turn off ice maker, unplug electoral connection, under bottom of ice maker, remove two screws (hex) under bottom of ice maker, lift up on it to unhook it, take it out. (dump out all ice ). remove back plate on back of ice maker (two screws), the solenoid is held in place with two brass screws, remove them, then remove ground wire from solenoid and two wires, that connect to it,(make a note of how wires go back !). put it all back together and your good to go. . i dont think its really the solenoid that goes out, its the housing that encases it, and you have to buy another solenoid thats encased. good luck
Parts Used:
Ice Maker Solenoid
  • steven from TONEY, AL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer filled up with ice leaking from ice maker shut off valve bad
It was real easy took the lines off one by one put them on the new unit one by one same with the three plugs than tighten new unit back on fridge.
Parts Used:
Refrigerator Water Inlet Valve
  • Harry from Orange City, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken glass
I was really impressed with how easy it was to navigate through your website and found the exact part I needed. I immediately received my glass shelf it took all of 2 seconds.
Parts Used:
Pan Cover Insert
  • marisa from pearland, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door shelf bin was broken
It was so easy, I just lifted the old one off and the new went right into place. No tools needed.
Parts Used:
Door Shelf Bin
  • Anna from Boca Raton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rust on Front Plate and Drive Blade
Downloaded a schematic of the ice container. Disassembled the ice container, keeping track of which different type of screws went where. Followed the schematic to ensure proper sequence of blades and spacers. Manually rotated unit prior to installing into the freezer in case of binding. Finished.
Parts Used:
DRIVE BLADE Front Plate
  • Wayne from Westford, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the water actuator broke off
it's very simple......take off the bottom plastic grate that catches the overspilled water, unscrew the 3 bottom screws, take off the black plate ( just lift up slightly), take out three more screws, then get the flashlight out. ......on top of the actuator, you will see 2 small silver-colored screws with very small silver-colored plates ( maybe 1/4 inch long), they hold the actuator into the unit. unscrew those and pull out the old actuator unit. You'll need to use your flashlight and pull the entire unit out to get access for replacment. Reverse the process for replacement, put in the actuator, screw in the 2 small silver-colored screws and there little plates, push the entire unti back into place, then screw in the remaining two sets of 3 screws......replace the faceplate and water grate and you're done.
Parts Used:
Water Dispenser Actuator
  • Sean from Oneonta, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Would Not Close
I stuck a small screw driver under the old switch & it came out really easy. I just unplugged the 2 electrical connectors, and removed the old switch. Installing the new one was just as easy. I am a woman!

I also want to say how FAST PartSelect gets their items to you. It came in ONE day!

Your repair stories are very helpful, I/we would have never known how easy this switch was to replace! Thank you!
Parts Used:
Light Switch
  • Janice M. from Washington, DC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch that shuts out light when the door closed broke
Removed the screws on the piece holding the switch which is at the front of the ceiling of the refrigerator box. Removed the old switch and replaced it. Very simple repair.
Parts Used:
Light Switch
  • NEIL from OCEAN CITY, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light switch did not operate correctly
Piece of cake! The new part just plugged in to socket and back into fridge frame. Appreciated how easy it was to order this part.
Parts Used:
Light Switch
  • Jeff from Lakeville, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator was freezing and freezer was not
Installed a new Defrost Thermostat.
Parts Used:
Defrost Thermostat Kit
  • Sally from FREEPORT, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water filter would not disconnect from OEM Water Filter Base
Disconnect the two water supply tubes at the base of the Water Filter Base. Using a 7/16" open end wrench, press up on the blue "O" rings to disconnect the tubes. Use a Using an 8" long magnetic phillips head screw driver I was able to unscrew the 4 short screws holding the original water filter base and the immovable attached water filter. Replacement was easy. Simply slide the new base into the fixed slot on the refrigerator and reinstall the 4 holding screws. Reconnect the water supply tubes to the Water Filter Base. Install a new water filter.
Parts Used:
Water Filter Base
  • Richard from SEATTLE, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!